Municipal water supply is one of the most critical infrastructure systems in any community. Every day, millions of people turn on a tap expecting clean, pressurized water — and the pumping equipment running silently inside treatment plants and booster stations makes that expectation a reality. Among the various pump types available to municipal engineers, split case pumps stand out as the preferred choice for large-volume, high-reliability water supply applications.
This guide explains what split case pumps are, how they work, why they dominate municipal water supply projects, and what engineers and procurement teams need to know before specifying them.
A split case pump — also called a double suction split case pump — is a centrifugal pump in which the pump casing is divided into two halves along a plane that passes through the shaft centerline. This split allows the internal components — impeller, wearing rings, and shaft — to be accessed by simply unbolting and lifting the upper half of the casing, without disturbing the motor, piping connections, or pump baseplate.

The most common configuration is the horizontal split case (HSC) pump, where the casing split is horizontal (the top half lifts off). Less commonly, vertical split case pumps are used where floor space is limited, with the casing split oriented vertically.
The defining hydraulic feature is the double-suction impeller: fluid enters the pump simultaneously from both sides of the impeller eye, flows symmetrically through the vane passages, and exits radially into the volute. This symmetrical inlet geometry is what makes split case pumps uniquely suited to high-flow municipal service.
Understanding the double-suction principle is essential to appreciating why split case pumps outperform single-suction alternatives in water supply service.
In a conventional single-suction centrifugal pump, fluid enters the impeller from one side only. This creates an unbalanced axial (thrust) load on the impeller and shaft — the pressure differential between the suction and discharge sides pushes the impeller axially. Managing this thrust requires heavy-duty thrust bearings, adds mechanical complexity, and consumes energy.
In a double-suction split case pump, fluid enters from both sides of the impeller simultaneously. The opposing suction flows create equal and opposite axial forces that cancel each other out, resulting in a theoretically zero net axial thrust. In practice, minor hydraulic asymmetries create small residual thrust loads, but these are a fraction of what single-suction pumps experience.
This hydraulic balance delivers three cascading benefits: reduced bearing loads, longer bearing life, and reduced shaft deflection — all critical for pumps running continuously in water supply service where Mean Time Between Maintenance (MTBM) is a primary specification criterion.
Municipal water supply engineers specify split case pumps over other pump types for a convergence of technical, economic, and operational reasons.
Municipal water supply demands are measured in millions of gallons per day (MGD). A single horizontal split case pump can deliver flow rates from 500 GPM to well over 100,000 GPM (approximately 114 m³/hr to 22,700 m³/hr), making them capable of serving large water treatment plants, regional transmission mains, and major booster stations without requiring multiple parallel smaller units.
High flow capacity from a single unit simplifies station layout, reduces installed cost, and decreases the number of rotating machines requiring maintenance.
Double-suction impellers achieve higher hydraulic efficiency than equivalent single-suction designs because the symmetrical inlet reduces velocity distortions, prerotation losses, and recirculation at the impeller eye. Top-tier horizontal split case pumps achieve wire-to-water efficiencies exceeding 88–92% at their best efficiency point (BEP).
For a municipal pumping station operating 8,760 hours per year, even a 2–3% efficiency improvement translates to substantial energy cost savings over the pump's 25–40 year service life. Energy is consistently the largest lifecycle cost element for water supply pumping stations — often representing 40–60% of total lifecycle cost.
The defining maintenance advantage of split case pumps is in-place maintenance without pipe removal. Because the casing splits horizontally, maintenance technicians can:
All of this occurs without breaking pipe flanges or moving the driver. In a 24/7 water supply operation where taking a pumping unit offline is a planned, coordinated event, this access speed is operationally significant. A pump teardown and inspection that might take three days on an end-suction pump can often be completed in one day on a horizontal split case unit.
Horizontal split case pumps are among the longest-lived pieces of rotating equipment in municipal infrastructure. Properly maintained units routinely operate for 30–50 years in water supply service. The AWWA (American Water Works Association) has documented case studies of split case pumps in continuous water supply service for over 40 years with only routine maintenance.
This longevity is a function of the balanced hydraulic design, conservative bearing loading, robust casing construction, and the fundamental simplicity of the double-suction impeller design.
The core component. Vanes curve backward from the rotation direction for stable pressure-flow characteristics. Impeller diameter is hydraulically selected to meet the station's design head and flow requirements. Bronze, cast iron, and stainless steel are standard material options, with stainless steel preferred for chloraminated water to resist denickelification.

Cast from ductile iron or cast iron for standard potable water service, or stainless steel for aggressive water chemistries. The mating faces of the casing halves are precision-machined for a metal-to-metal fit — no gasket is used in most modern designs, preventing deterioration and potential leak paths.

The shaft must be sized for rigidity, not just strength. AWWA C702 (the governing standard for cold-water horizontal split case pumps) specifies maximum allowable shaft deflection. Replaceable shaft sleeves protect the shaft in the seal area, extending shaft life significantly.

Modern municipal split case pumps are typically specified with mechanical seals for zero-drip performance, compliance with water loss reduction programs, and reduced maintenance compared to traditional compression packing. Packing is still specified in some raw water intake applications where solids in the water would damage seal faces.
Anti-friction (ball or roller) bearings in oil-bath or grease-lubricated housings support the shaft. For large pumps and continuous-duty municipal service, oil-lubricated sleeve bearings are sometimes specified for their lower noise signature and longer life.

The pump and motor are mounted on a common fabricated steel baseplate, grouted to a concrete foundation. Flexible jaw or disc couplings transmit motor torque while accommodating thermal expansion and minor residual misalignment.

Any split case pump specified for a municipal water supply project in the United States should comply with AWWA C702 — Standard for Cold-Water Meters–Compound Type, for Customer Service... specifically, for pumps: AWWA C700-series and the applicable Hydraulic Institute Standards (ANSI/HI 1.1-1.5, 1.3). These standards establish minimum material requirements, hydraulic performance testing protocols, and construction quality criteria.
One of the most critical — and most frequently violated — design rules is selecting the pump so that its normal operating point falls within 70–120% of the BEP flow rate. Operating chronically at low-flow (left of BEP) causes internal recirculation, vibration, and premature impeller damage. Operating far right of BEP risks cavitation and motor overload.
Municipal pumping stations with variable demands should include variable frequency drives (VFDs) on at least one duty pump to track system demand while maintaining operation near BEP across a range of flows.

Cavitation is the enemy of any centrifugal pump, and municipal split case pumps are not immune. The system designer must verify that the Net Positive Suction Head Available (NPSHa) at the pump suction exceeds the Net Positive Suction Head Required (NPSHr) by a suitable margin — typically a minimum 2-foot (0.6 m) safety margin per HI standards, with 3–5 feet recommended for critical applications.
For high-service pump stations drawing from clearwells, suction head is usually adequate. For booster stations at the end of long transmission mains, NPSHa can be marginal and warrants careful hydraulic analysis.
Related Reading: Understanding Cavitation and NPSH
Good municipal engineering practice — and most state drinking water program regulations — requires that a pumping station maintain its firm capacity (design flow with the largest single pump out of service) at all times. For a station requiring 10 MGD firm capacity, this typically means two 10 MGD pumps (one duty, one standby), or three pumps each rated at 5 MGD (two duty, one standby).
Split case pumps' high reliability supports a 1+1 configuration that would be higher risk with less dependable equipment.
The AWWA M52 manual (Water Transmission and Distribution) recommends lifecycle cost analysis — not first cost — as the basis for pump selection in municipal projects. For a pumping station with a 30-year design life, energy costs will typically dwarf initial capital costs. Split case pumps' high efficiency, combined with VFD operation, consistently delivers the lowest lifecycle cost in high-flow water supply applications.
| Factor | Horizontal Split Case | Vertical Split Case |
|---|---|---|
| Maintenance access | Excellent (top half lifts off) | Moderate (front half removed) |
| Floor space | Larger footprint | Smaller footprint |
| NPSH characteristics | Standard | Can be better (lower installation) |
| Typical flow range | 500–100,000+ GPM | 500–50,000 GPM |
| Municipal preference | Strong majority | Site-constrained applications |
| Driver mounting | Separate, on baseplate | Can be close-coupled |
Horizontal split case pumps dominate municipal water supply applications. Vertical split case units are selected primarily where pump room footprint is constrained — such as underground pump stations in dense urban environments — or where the hydraulic layout benefits from a lower pump centerline elevation.

Split case pumps are found throughout the municipal water supply chain:
Maximizing the service life of municipal split case pumps requires a structured preventive maintenance program:
The goal of a well-structured PM program is to eliminate unplanned failures entirely — a realistic objective for horizontal split case pumps given their inherent mechanical robustness.
Split case pumps have earned their dominant position in municipal water supply infrastructure through decades of proven performance. Their double-suction hydraulic design delivers high flow capacity, exceptional efficiency, and mechanical balance that minimizes bearing and seal wear. The split casing design enables in-place maintenance that reduces downtime in systems where continuous water delivery is a public health imperative.
For municipal engineers, utility managers, and infrastructure planners, the selection of horizontal split case pumps for high-flow water supply service is not simply a convention — it is the product of rigorous engineering experience, lifecycle cost optimization, and a deep operational understanding of what water supply reliability demands.
Specify them correctly, operate them near BEP, maintain them systematically, and split case pumps will deliver clean water to your community for generations.